86
b. Drag and place the line along the path where the objects will be moving. The larger icon
indicates the point closer to the camera.
c. Select Define Object Size. Click the larger icon
and click to pause the live
view. Use the mouse to outline the maximum size of objects on the live view.
d. Click the smaller icon
and repeat the step above to define the minimum size of
objects when they are further from the camera.
4. In the Setting section, there are two kinds of alarm modes:
Alarm Mode 1: The alarm sets off when the target object moves through the first detection
zone and touches the second detection zone in the defined direction.
Alarm Mode 2: The alarm sets off when the target object moves through the first detection
zone and its center moves through the second detection zone in the defined direction.
5. To set up alarm devices, configure any or both of the following options.
Invoke Alarm: Enable the computer alarm when an object enters the defined region. Click
the button next to the option to assign a .wav sound file.
Output Module: Enable an installed output device when an object enters the defined region.
Assign the output module and pin number.
6. To test your alarm settings, select Live from the Test Count drop-down list and click Test. When
intrusion objects are detected, the configured computer alarm or output device will be activated.
Optionally adjust the Sensitivity slider as needed.
7. Click OK to apply the setting.
8. Enable monitoring to start intrusion detection. The detected intruding objects are indicated on the
live view with red boxes.
When an intrusion event occurs, the configured computer alarm or output device will be activated, and
the event will be recorded as Intruder in the System Log for later retrieval
More options in the Alarm dialog box:
Show Alarm Regions and Skip Frame: See the same options in Object Counting above.
Never Recycle: Alarm-triggered events will never be recycled if selected.