Miscellaneous—Operational Checkout
Continued on next page KR46761,0001414 -19-01AUG18-47/50
Drive 20 m (66 ft) From a Running Start (check in forward and reverse
with travel mode switch in FAST position)
Zaxis260F-FE-6N Forestry Excavator
(S.N. —260024)
14.8—16.8 s
Zaxis260FLC-FE-6N Forestry Excavator
(S.N. 260025— )
17.6—19.6 s
Drive 20 m (66 ft) From a Running Start (check in forward and reverse
with travel mode switch in SLOW position)
Zaxis260F-FE-6N Forestry Excavator
(S.N. —260024)
23.8—25.8 s
Zaxis260FLC-FE-6N Forestry Excavator
(S.N. 260025— )
27.2—29.2 s
Track Raised for 3 Revolutions From a Running Start (check in forward
and reverse with travel mode switch in SLOW position)
Zaxis260F-FE-6N Forestry Excavator
(S.N. —260024)
31—37 s
Zaxis260FLC-FE-6N Forestry Excavator
(S.N. —260024)
33—39 s
Zaxis260F-FE-6N Forestry Excavator
(S.N. 260025— )
40—46 s
Zaxis260FLC-FE-6N Forestry Excavator
(S.N. 260025— )
43—49 s
Processor—Specication
Boom Raise (cylinder extend)—Cycle
Time.................................................................................................................3.0—3.6 s
Boom Lower (cylinder retract)—Cycle
Time.................................................................................................................2.8—3.4 s
Arm In (cylinder extend)—Cycle Time.............................................................3.0—3.6 s
Arm Out (cylinder retract)—Cycle Time...........................................................2.3—2.9 s
Swing Left or Right, 3 Revolutions From
a Running Start—Cycle Time.......................................................................14.0—16.0 s
Drive 20 m (66 ft) From a Running Start (check in forward and reverse
with travel mode switch in FAST position)
Zaxis260F-FE-6N Processor (S.N.
—260024)
14.8—16.8 s
Zaxis260FLC-FE-6N Processor (S.N.
260025— )
17.6—19.6 s
Drive 20 m (66 ft) From a Running Start (check in forward and reverse
with travel mode switch in SLOW position)
Zaxis260F-FE-6N Processor (S.N.
—260024)
23.8—25.8 s
Zaxis260FLC-FE-6N Processor (S.N.
260025— )
27.2—29.2 s
4-2-42
112321
PN=322