Hitachi ZAXIS 260FLC-FE-6N

User Manual - Page 214

For ZAXIS 260FLC-FE-6N.

PDF File Manual, 383 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Maintenance—As Required
KR46761,00013A6 -19-22SEP16-1/1
KR46761,0001168 -19-23MAY16-1/1
Clean Auxiliary Hydraulic Cooler Screen—If
Equipped
CAUTION: Clear area of bystanders and wear
personal protection equipment, including
eye protection. Reduce compressed air to
less than 196 kPa (1.96 bar) (28.4 psi) when
using for cleaning purposes.
1. Remove cap screws (1) and lift auxiliary hydraulic
cooler screen (2) to remove.
2. Attach an air wand to an air compressor and blow out
dirt and debris from auxiliary hydraulic cooler screen.
3. Install auxiliary hydraulic cooler screen and cap
screws.
1— Cap Screw (4 used) 2— Auxiliary Hydraulic Cooler
Screen
TX1224061 —UN—22SEP16
Auxiliary Hydraulic Cooler Screen
Lubricate Door Hinges
Lubricate all door hinge grease ttings until grease
escapes at joints. See Track Adjuster, Working Tool
Pivot, Swing Bearing, and Swing Bearing Gear Grease.
(Section 3-1.)
TX1216139 —UN—23MAY16
Door Hinge Grease Fitting
3-3-10
112321
PN=212