Maintenance—Every 250 Hours
Continued on next page TX,HYBATT,CHK -19-24APR20-1/2
Check Hybrid Battery Electrolyte Level—If
Equipped
CAUTION: Battery gas can explode. Keep sparks
and ames away from batteries. Use a ashlight
to check battery electrolyte level.
NEVER check battery charge by placing
a metal object across the posts. Use a
voltmeter or hydrometer.
ALWAYS remove grounded (-) battery clamp
rst and replace it last.
Sulfuric acid in battery electrolyte is
poisonous. It is strong enough to burn skin,
eat holes in clothing, and cause blindness
if splashed into eyes.
Avoid the hazard by:
1. Filling batteries in a well-ventilated area.
2. Wearing eye protection and rubber gloves.
3. Avoiding breathing fumes when
electrolyte is added.
4. Avoiding spilling or dripping electrolyte.
5. Using proper jump start procedure.
If acid is spilled on skin:
1. Flush skin with water.
2. Apply baking soda or lime to help
neutralize the acid.
3. Flush eyes with water for 15–30 minutes.
4. Get medical attention immediately.
If acid is swallowed:
1. Do not induce vomiting.
TS203 —UN—23AUG88
Avoid Acid Burns
2. Drink large amounts of water or milk but
do not exceed 1.9 L (2 qt).
3. Get medical attention immediately.
1. Remove battery box cover.