Maintenance—As Required
Continued on next page KR46761,00010C5 -19-14SEP20-2/4
Removing Cab Recirculating Air Filter
TX1222364 —UN—31AUG16
Cab Service Door
TX1211685 —UN—26FEB16
Cab Recirculating Air Filter Cover
TX1211687 —UN—26FEB16
Cab Recirculating Air Filter
1— Cab Service Door
2— Cap Screw (4 used)
3— Latch
4— Cover
5— Cab Recirculating Air Filter
1. Open cab service door (1).
2. Remove cap screws (2) and release latch (3).
3. Remove cover (4) to access cab recirculating air lter
(5).
4. Squeeze tabs on each side of the lter to remove.
Cleaning Filters