Maintenance—Every 250 Hours
KR46761,0001245 -19-20JUN16-1/1
Check Pump Drive Gear Case Oil Level
1. Park machine on a level surface.
IMPORTANT: Turbocharger can be damaged
if procedure to shut down engine is
not done properly.
2. Run engine at slow idle speed without load for 5
minutes.
3. Stop engine.
4. Open right rear service door to access pump drive
gear case.
5. Remove dipstick (1). Wipe dipstick clean and insert
completely into tube.
6. Remove dipstick. Oil level must be approximately
halfway below the H mark. Insert dipstick.
7. If necessary, remove ll plug (2) and add oil. See
Pump Drive Gear Case Oil. (Section 3-1.)
8. Install ll plug.
9. Check oil level on dipstick.
10. Close service door.
1— Dipstick 2— Fill Plug
TX1217831 —UN—19JUL16
Pump Drive Gear Case
T145092 —UN—31AUG01
Dipstick
3-8-4