Maintenance—Every 10 Hours or Daily
Continued on next page KR46761,000138B -19-14DEC16-1/3
Check Hydraulic Tank Oil Level
IMPORTANT: Prevent damage to hydraulic system
components. DO NOT run engine without
oil in hydraulic tank.
Avoid machine damage. Mixing different oil
types can degrade lubricant and machine
performance. Oil manufacturers engineer
their oils to meet certain specications and
performance requirements.
Avoid machine damage. This excavator is
factory lled with Super EX 46HN extended
life zinc-free hydraulic oil. Avoid servicing
this excavator with products that do not meet
this specication. If oils have been mixed or if
alternate service oils are desired, the complete
hydraulic system needs to be completely
ushed by an authorized dealer.
1. Park machine on a level surface, and position machine
with arm cylinder fully retracted and bucket cylinder (if
equipped) fully extended.
IMPORTANT: Turbocharger can be damaged
if procedure to shut down engine is
not done properly.
2. Run engine at slow idle speed without load for 5
minutes.
3. Stop engine.
4. Open right front service door to access hydraulic oil
level gauge (1) on hydraulic tank.
TX1217687 —UN—16JUN16
Hydraulic Oil Level Sight Gauge
1— Hydraulic Oil Level Gauge
5. Check hydraulic oil level gauge on hydraulic tank. Oil
must be between marks on window.
3-4-3
112321
PN=218