Maintenance—Every 500 Hours
KR46761,00013B2 -19-20OCT16-1/2
KR46761,00013B2 -19-20OCT16-2/2
KR46761,0001390 -19-29SEP16-1/1
Clean Radiator, Oil Cooler, Charge Air
Cooler, and Fuel Cooler
CAUTION: Prevent possible injury from rotating
fan and ying debris. Shut off engine before
opening door. Avoid rotating fan and fan blast.
Clear area of bystanders and wear personal
protection equipment, including eye protection.
Reduce compressed air to less than 196 kPa (1.96
bar) (28.4 psi) when using for cleaning purposes.
1. Stop engine.
2. Open engine cover and left rear service door.
3. Remove cooler inlet screen. See Clean Cooler Inlet
Screen in this section.
4. Attach an air wand to an air compressor and blow dirt
and debris back through cooling system.
5. Close panel and install cap screws.
TX1225972 —UN—12OCT16
Cooler Cores
1— Hydraulic Oil Cooler
2— Radiator
3— Charge Air Cooler
4— Fuel Cooler
5— Air Conditioner Condenser
6. Close service door and engine cover.
If machine is equipped with a hydraulic reverse fan
function, use the reversing fan switch to clean the cooling
system. The reversing fan switch is located on the left
console.
IMPORTANT: Prevent machine damage from
overheating. Do not manually reverse fan
immediately after last completion. Wait 1
minute before reactivating.
NOTE: Reversing fan is more effective at higher
engine speeds.
The reversing fan switch has three positions:
AUTO: Every 60 minutes, the radiator cooling fan will
automatically reverse direction for 30 seconds without
intervention from the operator when engine rpm is above
auto-idle speed. The default time setting is 60 minutes.
To adjust time setting, see an authorized Hitachi dealer.
OFF: Fan resumes normal operation.
MANUAL: Press and hold right side of switch to reverse
fan. Fan will stop reversing when switch is released or
when 1 minute has passed.
TX1000844A —UN—29NOV05
Reversing Fan Switch (if equipped)
When reversing fan is activated, the reversing fan
indicator will appear on the monitor display.
Take Fluid Samples
See an authorized Hitachi dealer for procedures and
sampling equipment. For more information, see Fluid
Sampling Test Ports. (Section 4-1.)
Diesel Fuel
Engine Coolant
Hydraulic Oil
Swing Gear Case Oil
Pump Drive Gear Case Oil
Travel Gear Case Oil
Cab Tilt Oil—rear entry cab only
3-9-4
112321
PN=239