Maintenance—Every 1500 Hours
KR46761,00013B0 -19-18OCT16-1/1
Replace Air Cleaner Elements
1. Open left front service door to access air cleaner.
2. Release latches (1) to unlock air cleaner cover (2).
3. Rotate air cleaner cover counterclockwise and remove.
4. Remove primary air lter element (3).
5. Remove secondary air lter element (4).
6. Clean the inside of the lter canister.
7. Install new lter elements, making sure the secondary
air lter element is centered in canister.
8. Install air cleaner cover and secure latches.
9. Close service door.
1— Latch (4 used)
2— Air Cleaner Cover
3— Primary Air Filter Element
4— Secondary Air Filter
Element
TX1224603 —UN—27SEP16
Air Cleaner Cover
TX1224604 —UN—27SEP16
Primary Air Cleaner Element
TX1224605 —UN—27SEP16
Secondary Air Cleaner Element
3-11-1