Miscellaneous—Operational Checkout
Continued on next page KR46761,0001414 -19-01AUG18-27/50
Travel Alarm Cancel
Switch Circuit Check
TX1213268 —UN—02JUN16
Left Console
TX1001227 —UN—14DEC05
Travel Alarm Cancel Switch
1— Travel Alarm Cancel Switch
2— Dome Light Switch
3— Horn Switch (processor only)
4— Reversing Fan Switch (if equipped)
5— Max Speed Program Switch (if equipped)
6— Hydraulic Oil Tank Pressure Vent Switch (if equipped)
CAUTION: Avoid possible injury. Machine will move during this check.
Make sure area is clear and large enough to operate machine.
NOTE: Travel alarm must operate for this check.
Place pilot shutoff lever in unlocked (DOWN) position.
Push travel pedals or levers and allow travel alarm to operate for a minimum of 13
seconds.
LISTEN: Does travel alarm sound? YES: Go to next check.
While continuing travel, press travel alarm cancel switch (1). NO: Check optional and
attachment connector
5 A fuse (marked OPT.
1 ALT/SAW) (F5). See
Replacing Fuses. (Section
4-1.)
LISTEN: Does travel alarm stop sounding? IF OK: See an authorized
Hitachi dealer.
4-2-22
112321
PN=302