Maintenance—Every 5000 Hours
KR46761,000126F -19-22AUG16-1/1
Drain and Rell Cab Tilt Oil—Rear Entry Cab
Only
1. Park machine on a level surface.
CAUTION: Turbocharger can be damaged
if procedure to shut down engine is not
done properly.
2. Run engine at slow idle speed without load for 5
minutes.
3. Stop engine.
4. Open cab service door (1) to access the cab tilt
hydraulic pump.
5. Open ll cap (3).
6. Remove drain plug (4) and allow oil to drain into a
container. Dispose of waste oil properly.
7. Install drain plug.
8. Remove ll cap and add oil. See Cab Tilt Oil—Rear
Entry Cab Only. (Section 3-1.)
Specication
Cab Tilt Tank
Oil—Capacity................................................................................... 3.3 L
3.4 qt
9. Install ll cap.
10. Check oil level on cab tilt oil tank. Oil level must be
at FILL line.
11. Close cab service door.
TX1213788 —UN—26APR16
Cab Service Door
TX1214917 —UN—18MAY16
Cab Tilt Hydraulic Pump
1— Cab Service Door
2— Cab Tilt Oil Tank
3— Fill Cap
4— Drain Plug
3-15-4