Loading ...
Loading ...
Loading ...
![](https://files.manualsfile.com/79478501-zaxis-260f-fe-6n/bgd2.png)
Maintenance—As Required
KR46761,00010C5 -19-14SEP20-4/4
Side Entry Cab
Removing Cab Fresh Air Filter
1. On the left side of the cab, remove cap screws (1).
2. Remove cover (2) to access cab fresh air lter (3).
3. Squeeze tabs on each side of the lter to remove.
Removing Cab Recirculating Air Filter
1. Move operator's seat forward to access cab
recirculating air lter (4) located under the rear deck.
2. Squeeze tabs on each side of the lter to remove.
Cleaning Filters:
CAUTION: Avoid injury from ying debris. Clear
area of bystanders and wear personal protection
equipment, including eye protection. Reduce
compressed air to less than 196 kPa (1.96 bar)
(28.4 psi) when using for cleaning purposes.
Clean lters using one of the following methods:
•
Use compressed air opposite to the normal air ow.
•
Wash lters with water. Soak the lters in warm, soapy
water for 5 minutes. Flush lter. Allow lter to dry before
installing.
Cab Fresh Air Filter Installation
1. Install lter.
2. Install cover and cap screws.
Cab Recirculating Air Filter Installation
1. Install lter.
2. Move operator’s seat into operating position.
1— Cap Screw (4 used)
2— Cover
3— Cab Fresh Air Filter
4— Cab Recirculating Air Filter
TX1211665 —UN—25FEB16
Cab Fresh Air Filter Cover
TX1211666 —UN—25FEB16
Cab Fresh Air Filter
TX1211690 —UN—26FEB16
Cab Recirculating Air Filter
3-3-6
112321
PN=208
Loading ...
Loading ...
Loading ...