Miscellaneous—Machine
KR46761,000127D -19-05JUL16-1/1
KR46761,000127E -19-05JUL16-1/1
Replacing Bucket Tooth Tip—Heavy-Duty
Bucket—If Equipped
1. Clean tooth (A) and tooth tip (B).
2. Insert lock removal tool under U-shaped pin (C).
CAUTION: Avoid possible injury. Pin may y
after pin is released from tooth tip. Keep a
rm grip on pin to prevent injury.
3. Remove pin.
4. Turn tooth tip counterclockwise and pull tooth tip up
to remove.
5. Clean tooth shank.
6. Replace U-shaped pin and tooth tip at the same time.
7. Insert tooth tip on shank turning tip clockwise.
8. Install U-shaped pin. The side of the pin with the
FRONT mark (D) must face tooth tip. Make sure pin is
rmly engaged over tooth tip.
A—Tooth
B—Tooth Tip
C—Pin
D—FRONT Mark
T6879EE —UN—06DEC88
Bucket Tooth Tip
T7527DO —UN—27JUN91
U-Shaped Pin
Replacing Bucket Teeth—TK Series—If
Equipped
IMPORTANT: Prevent machine damage. Check
bucket teeth periodically so that wear does
not extend to the bucket tooth shank.
1. Remove pin (1) by rotating counterclockwise 180°
using a ratchet and socket.
2. Remove tooth.
3. Inspect pin and rubber locks (2) for damage. Replace
if necessary.
4. Position the new tooth over the tooth shank.
5. Install pin by rotating clockwise 180°.
1— Pin
2— Rubber Lock (2 used)
TX1150806 —UN—10JAN14
Pin
TX1150895 —UN—10JAN14
Rubber Lock
4-1-15