Miscellaneous—Operational Checkout
Continued on next page KR46761,0001414 -19-01AUG18-22/50
Engine Speed Dial Check
A
C
C
O
N
S
T
A
R
T
5
9
3
8
54
0
2
7
1
6
OFF
2
MODE
1
A/I
ON
A/I
OFF
OFF
OFF
INT
ON
PUSH
HL
PUSH
TUNE/AM-FM
PUSH
MODE
PUSH
MENU/SET
min
-1
L
H
PUSH
VOL/PWR
PUSH
/VOL
/PWR
1
2
3
4
TX1086753 —UN—11JAN11
Switch Panel
1— Engine Speed Dial
2— Auto-Idle Switch
3— Travel Mode Switch
4— Power Mode Button
Turn auto-idle switch (2) to A/I OFF.
Place pilot shutoff lever in locked (UP) position.
Turn engine speed dial (1) clockwise.
LISTEN: Does engine speed increase? YES: Go to next check.
Turn engine speed dial counterclockwise.
NO: Check data converter
and main controller battery
power 5 A fuse (marked
CONTROLLER) (F10).
See Replacing Fuses.
(Section 4-1.)
LISTEN: Does engine speed decrease? IF OK: See an authorized
Hitachi dealer.
4-2-17