Hitachi ZAXIS 260FLC-FE-6N

User Manual - Page 274

For ZAXIS 260FLC-FE-6N.

PDF File Manual, 383 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Miscellaneous—Machine
KR46761,00013E1 -19-25OCT16-2/2
KR46761,000141A -19-07NOV16-1/1
KR46761,00010C9 -19-01FEB16-1/1
JDLink is a trademark of Deere & Company
Fluid Sampling Test Ports
Open right rear service door to access engine oil sampling
test port (1) and hydraulic oil sampling test port (2).
1— Engine Oil Sampling Test
Port
2— Hydraulic Oil Sampling Test
Port
TX1227820 —UN—07NOV16
Engine Oil Sampling Test Port
TX1227822 —UN—07NOV16
Hydraulic Oil Sampling Test Port
Keep ROPS Installed Properly
CAUTION: Make certain all parts are installed
correctly if the roll-over protective structure
(ROPS) is loosened or removed for any reason.
Tighten mounting bolts to proper torque.
The protection offered by ROPS will be
impaired if ROPS is subjected to structural
damage, is involved in an overturn incident,
or is in any way altered. A damaged ROPS
should be replaced, not reused.
When installation of equipment on a machine necessitates
loosening or removing ROPS, mounting bolts must be
tightened to specication.
Specication
ROPS Mounting
Bolts—Torque..............................................................................620 N·m