Maintenance—Every 250 Hours
TX,HYBATT,CHK -19-24APR20-2/2
IMPORTANT: If water is added to batteries during
freezing weather, batteries must be charged
after water is added to prevent batteries from
freezing. Charge battery using a battery
charger or by running the engine.
2. Fill each cell to within the specied range with distilled
water. DO NOT overll.
CAUTION: Prevent possible injury. ALWAYS
remove grounded (-) battery clamp rst
and replace it last.
3. Disconnect battery clamps, grounded clamp rst.
4. Clean battery terminal (4) and clamps with a stiff brush.
5. Apply lubricating grease (5) around battery terminal
base only.
6. Install and tighten clamps, grounded clamp last.
1— Battery Post
2— Fill Tube
3— Electrolyte Level Range
4— Battery Terminal
5— Lubricating Grease
TX1208617 —UN—05JAN16
Battery Terminal and Fill Hole
T137536 —UN—25JAN01
Fill Level
4
5
TX1265575 —UN—03OCT18