LIN Trigger and Serial Decode
Please take the order of
Setup for LIN Signals
,
LIN Trigger
and
LIN Serial Decode
to
trigger and decode the signals.
Setup for LIN Signals
There are two steps of setting the LIN signal, connecting the signal to oscilloscope,
specifying the parameters of each input signal.
1. Press the
Decode
button to enter the DECODE function menu.
2. Press the
Decode
softkey and select the desired slot (Decode1 or Decode2).
3. Press the
Protocol
softkey and then select
LIN
by turning
Universal Knob
.
4. Press the
Signal
softkey to enter the
SIGNAL
menu as Figure 58 shows.
Figure 62 LIN SIGNAL Menu
5. Press the
Source
softkey to select the channel that is connected to the LIN signal.
6. Press the
Threshold
softkey and set the LIN signals threshold voltage level by
Universal Knob
. The threshold voltage level is for decoding, and it will be regard as
the trigger voltage level when set the trigger type to serial.
7. Press the softkey to return previous menu.
8. Press the
Configure
softkey to enter the
BUS CONFIG
menu.
9. Press the
Baud
softkey to set baud rate.
The baud rate can be set as predefined value.
If the desired baud rate is not listed, select
custom
option, press the
Custom
and
turn the
Universal Knob
to set the desired baud rate.