Mobile Printing Systems
CPCL Programming Manual
Section 14
Configuration/
Control
Commands
pg. 14-213
continued
internal_wired.ip.arp_interval
type: getvar; setvar
This parameter allows you to specify the Address Resolution Protocol (ARP) interval or the ARP cache
time out for the internal wired print server.
getvar result
The ARP interval or the ARP cache time out value for the internal wired print
server..
Example
Description
Gets the printer to respond with the ARP interval or the ARP
cache time out value for the internal wired print server.
Syntax ! U1 getvar ”internal_wired.ip.arp_interval
Result “ 0
setvar choices
Values: 0-30
Default 0
Example
Description
Instructs the printer to change the ARP interval or the ARP cache
time out for the internal wired print server.
Syntax ! U1 setvar “internal_wired.ip.arp_interval” “0