input capture parameter (continued)
getvar result The current input capture mode.
Example
Description Get current staus of input capture mode
Syntax ! U1 getvar “input.capture”
Result “off
setvar choices “print, “run”, “off
Default “off
Example 1
Description Place the printer in “print” input capture mode
Syntax ! U1 setvar “input.capture” “print
Result Printer will enter diagnostics capture mode. Any data received
by the printer will be saved to files named “in???.dmp. The
data’s text & hexadecimal representation will be printed.
Example 2
Description Place the printer in “run” input capture mode.
Syntax ! U1 setvar “input.capture” “run”
Result Printer will enter diagnostics capture mode. Any data received
by the printer will be saved to files named in “???.dmp” prior
to being processed by the printer.