CPCL Programming Manual
Section 9
Line Print
Mode
pg. 9-3
Special Commands Using the Utility Function
The printer can execute several utility commands at once or one at a time.
! U
SETLP 7 0 24
PAGE-WIDTH 720
PRINT
This line is printed as raw text.
These lines are in font 7 size 0
! U1 SETLP 7 0 24
! U1 PAGE-WIDTH 720
This line is printed as raw text.
These lines are in font 7 size 0.
The “! UTILITIES” command, or “! U” for short, must be ended by the terminator “PRINT” followed
by a CR/LF (Carriage Return/Line Feed, or “Enter”) to end the utility session. The “! U1” command only
executes one utility command and must be followed by a CR/LF. Also, the “! U1” command can be placed
ANYWHERE in a text line to execute the command.
Example:
Although this text is all on the same line, ! U1 SETLP 5 0 24 (CR/LF)
this font is new.
To change the default settings for the printer, any of these commands can be placed in an AUTOEXEC.
BAT file. Please see the “Batch Files” section in “Printer Configuration and Setup” in Section 13 of this
manual.