Status Code (hex) Definition
39 PPS not accepted (no answer from card)
3B Early answer of the card during the activation
40 Card deactivated
55 Unknown command
80 Card mute (after power on)
81 Time out (waiting time exceeded)
83 4 parity errors in reception
84 4 parity errors in transmission
86 Bad FiDi
88 ATR duration greater than 19200 etus (E.M.V.)
89 CWI not supported (E.M.V.)
8A BWI not supported (E.M.V.)
8B WI (Work waiting time) not supported (E.M.V.)
8C TC3 not accepted (E.M.V.)
8D Parity error during ATR
90 3 consecutive parity errors in T=1 protocol
91 SW1 different from 6X or 9X
92 Specific mode byte TA2 with b5 byte=1
93 TB1 absent during a cold reset (E.M.V.)
94 TB1 different from 00 during a cold reset (E.M.V.)