Mobile Printing Systems
CPCL Programming Manual
Section 14
Configuration/
Control
Commands
pg. 14-109
continued
ip.mirror.feedback.path
type: getvar; setvar
This parameter identifies where the feedback file is stored on the mirroring server.
getvar result The path on the mirroring server that stores the feedback file.
Example
Description This parameter retrieves the path on the mirroring server that the
printer is currently using to store the feedback file.
Syntax ! U1 getvar “ip.mirror.feedback.path”
Result “Zebra/feedback”
setvar choices
Values: alphanumeric text (1 to 50 characters)
Default “Zebra/feedback”
Example
Description This parameter instructs the printer to set the mirror frequency.
Syntax ! U1 setvar “ip.mirror.feedback.path” “Zebra/feedback”
ip.mirror.feedback.freq
type: getvar; setvar
This parameter specifies the time interval (in minutes) between performing feedback file uploads.
getvar result The amount of time (in min.) the printer will wait between feedback file uploads.
Example
Description This parameter retrieves the number of minutes to wait between
feedback file uploads.
Syntax ! U1 getvar “ip.mirror.feedback.freq”
Result “0”
setvar choices
Values: numeric value (0-65535)
Default “0”
Example
Description This parameter instructs the printer to set the number of minutes
to wait between feedback file uploads.
Syntax ! U1 setvar “ip.mirror.feedback.freq” “0”