Mobile Printing Systems
CPCL Programming Manual
Section 10
Advanced
Utilities
pg. 10-49
continued
Example 2: Send Raw Data
Input:
! DF autoexec.bat
! UTILITIES
SRF-ACCESS
BHT-MODE RAW
END-SRF-ACCESS
PRINT
Output:
Data Record:
|----10----|---8----|--------20----------|
COMTEC^^^^ ^INFO^^^ ^SYSTEMS^^^^^^^^^^^^
Data Sent to printer:
COMTEC^^^^ ^INFO^^^ ^SYSTEMS^^^^^^^^^^^^
Example 3: Counted String
Input:
! DF autoexec.bat
! UTILITIES
SRF-ACCESS
BHT-MODE COUNTED-STRING
END-SRF-ACCESS
PRINT
Output:
Data Record:
|10|8|20|
6COMTEC^^^ 6^INFO^^ 7SYSTEMS^^^^^^^^^^^^
Data Sent to printer:
COMTEC^INFO^SYSTEMS