D-Link DGS-3130 Gigabit Layer 3 Stackable Managed Switches

User Manual - Page 441

For DGS-3130.

PDF File Manual, 489 pages, Read Online | Download pdf file

DGS-3130 photo
Loading ...
Loading ...
Loading ...
DGS-3130 Series Layer 3 Stackable Managed Switch Web UI Reference Guide
430
Parameter Description
ACL Name Enter the name of the ACL that will be used here. This name can be up to 32
characters long. Click the Please Select button to select an existing ACL from
the list.
Action Select the action to be taken here. Options to choose from are Add and Clear.
Click the Apply button to accept the changes made.
The fields that can be configured in IPv4 Ping are described below:
Parameter Description
Target IPv4 Address Select and enter an IP address to be pinged.
Domain Name Select and enter the domain name of the system to discover.
Ping Times
Enter the number of times desired to attempt to Ping the IPv4 address
configured in this window. Users may enter a number of times between 1 and
255. Tick the Infinite check box to keep sending ICMP Echo packets to the
specified IP address until the program is stopped.
Timeout
Select a timeout period between 1 and 99 seconds for this Ping message to
reach its destination. If the packet fails to find the IP address in this specified
time, the Ping packet will be dropped.
Length Enter the length value here. This specifies the number of data bytes to send.
The default value is 56, which translates into 64 ICMP data bytes when
combined with the 8 bytes of ICMP header data. It does not include any VLAN
or IEEE 802.1Q tag length. The range is from 1 to 1420 bytes.
ToS Enter the ToS value here. This is used to configure the QoS on ICMP
datagrams. The range is from 0 to 255.
Stop Time
Enter the stop time value here. This specifies to stop the ping after the amount
of times entered here. If this value is configured as 0, then the ping can only be
stopped by clicking the Stop button manually. The range is from 0 to 99.
Source IPv4 Address Enter the source IPv4 address. If the current Switch has more than one IP
address, you can enter one of them to this field. When entered, this IPv4
address will be used as the packets’ source IP address sent to the remote host,
or as primary IP address.
Click the Start button to initiate the Ping Test for each individual section.
The fields that can be configured in IPv6 Ping are described below:
Parameter Description
Target IPv6 Address Enter an IPv6 address to be pinged.
Domain Name Select and enter the domain name of the system to discover.
Ping Times Enter the number of times desired to attempt to Ping the IPv6 address
configured in this window. Users may enter a number of times between 1 and
255. Tick the Infinite check box to keep sending ICMP Echo packets to the
specified IPv6 address until the program is stopped.
Timeout Select a timeout period between 1 and 99 seconds for this Ping message to
reach its destination. If the packet fails to find the IP address in this specified
time, the Ping packet will be dropped.
Length Enter the length value here. This specifies the number of data bytes to send.
The default value is 56, which translates into 64 ICMP data bytes when
combined with the 8 bytes of ICMP header data. It does not include any VLAN
or IEEE 802.1Q tag length. The range is from 1 to 1420 bytes.
Stop Time Enter the stop time value here. This specifies to stop the ping after the amount
of times entered here. If this value is configured as 0, then the ping can only be
stopped by clicking the Stop button manually. The range is from 0 to 99.
Loading ...
Loading ...
Loading ...