DGS-3130 Series Layer 3 Stackable Managed Switch Web UI Reference Guide
395
Parameter Description
• Error Frame Seconds - This feature is used to enable notifying the
Ethernet OAM error frame second event and configure the monitor
threshold and window on the specified port.
• Error Frame Period - This feature is used to enable notifying the Ethernet
OAM error frame period event and configure the monitor threshold and
window on the specified port.
Notify State Select to enable or disable the notify state here.
Threshold Enter the threshold value here.
• When Error Symbol is selected as the link monitor, enter the number of
symbol errors here. If symbol errors occur in the specified window and it
exceeds the threshold value, then the event is generated. The range is
from 0 to 4294967295.
• When Error Frame is selected as the link monitor, enter the number of
frame errors here. If the error frames occur in the specified window and
exceeds the threshold value, then an error frame event is triggered. The
range is from 0 to 4294967295.
• When Error Frame Seconds is selected as the link monitor, enter the
number of error frames in seconds here. If the number of the error frames
occurred in the specified window and exceeds the threshold value, then
the frame event is triggered. The range is from 1 to 900 seconds.
• When Error Frame Period is selected as the link monitor, enter the
number of frame errors that must occur for this event to be triggered here.
The range is from 0 to 4294967295.
Window Enter the window value here.
• When Error Symbol is selected as the link monitor, enter the amount of
time over which the threshold is defined here. If threshold symbol errors
occur within the period, an event notification OAM PDU should be
generated with an error symbol period event TLV, indicating that the
threshold has been crossed in this window. The range is from 10 to 600
deciseconds.
• When Error Frame is selected as the link monitor, enter the amount of
time over which the threshold is defined here. If the threshold frame errors
occur within the period, an event notification OAM PDU will be generated
with an error frame event TLV, indicating that the threshold has been
crossed in this window. The range is from 10 to 600 deciseconds.
• When Error Frame Seconds is selected as the link monitor, enter the
amount of time over which the threshold is defined here. If threshold frame
errors occur within the period, an event notification OAM PDU will be
generated with an error frame seconds summary event TLV indicating that
the threshold has been crossed in this window. The range is from 100 to
9000 deciseconds.
• When Error Frame Period is selected as the link monitor, enter the
number of frames over which the threshold is defined here. If threshold
frame errors occur within the period, an event notification OAM PDU
should be generated with an error frame period event TLV indicating that
the threshold has been crossed in this window. The lower bound is the
number of minimum frame-size frames that can be received in 100ms on
the underlying physical layer. The upper bound is the number of minimum
frame-size frames that can be received in one minute on the underlying
physical layer. The range is from 148810 to 892860000.
Click the Apply button to accept the changes made.
The fields that can be configured in Ethernet OAM Configuration Table are described below:
Parameter Description
Unit Select the Switch unit ID that will be used here.
From Port - To Port Select the Switch port range that will be used here.
Loading ...