DGS-3130 Series Layer 3 Stackable Managed Switch Web UI Reference Guide
260
Parameter Description
• When selecting the Set-1P-Transmit option, enter the 1P transmit
value in the space provided. This value sets the 802.1p value and
transmits the packet with the new value.
• When selecting the Transmit option, packets will be transmitted
unaltered.
• When selecting the Set-DSCP-1P option, enter the IP DSCP and 1P
transmit values in the spaces provided.
Violate Action Select the violate action here. The violate action specifies the action to take on
packets that violate the normal and maximum burst sizes for singe rate policing.
It specifies the action to take for those packets that did not conform to both CIR
and PIR. For a single rate policer, if the violate action is not specified, it will
create a single-rate two-color policer. For a two-rate policer, if the violation
action is not specified, the default action is equal to the exceed action. Options
to choose from are None, Drop, Set-DSCP-Transmit, Set-1P-Transmit,
Transmit, and Set-DSCP-1P.
• When selecting the None option, no action will be taken.
• When selecting the Drop option, the packet will be dropped.
• When selecting the Set-DSCP-Transmit option, enter the IP DSCP
value in the space provided. This value sets the IP differentiated
services code point (DSCP) value and transmits the packet with the
new IP DSCP value.
• When selecting the Set-1P-Transmit option, enter the 1P transmit
value in the space provided. This value sets the 802.1p value and
transmits the packet with the new value.
• When selecting the Transmit option, packets will be transmitted
unaltered.
• When selecting the Set-DSCP-1P option, enter the IP DSCP and 1P
transmit values in the spaces provided.
Color Aware Select the color aware option here. Options to choose from are Enabled and
Disabled. When color aware is disabled, the policer works in the color blind
mode. When color aware is enabled, the policer works in the color aware mode.
Click the Apply button to accept the changes made.
Click the Delete button to remove the specific entry.