corresponded to UART7 and UART8. Wiring Interface is
corresponded to UART1, UART4, UART6, UART6, and Lane.
The access control board descripons are as follows:
UART2/UART3 Jumper Cap
Reserved serial port. Use the jumper cap to switch the serial
port communicaon mode. You can switch between the RS-485
communicaon mode and the RS-232 communicaon mode.
By default, it is in RS-485 communicaon mode.
UART6 Jumper Cap
Use the jumper cap to switch the serial port communicaon
mode with the sub lane controller. You can switch between the
RS-232 communicaon mode and the RS-485 communicaon
mode. By default, it is in RS-232 communicaon mode.
UART5 Jumper Cap
Use the jumper cap to switch the serial port communicaon
mode with the sub lane controller. You can switch between the
RS-485 communicaon mode and the RS-232 communicaon
mode. By default, it is in RS-485 communicaon mode.
UART1 Jumper Cap
Use the jumper cap to switch the serial port communicaon
mode with the main lane controller. You can switch between
the RS-485 communicaon mode and the RS-232
communicaon mode. By default, it is in RS-485
communicaon mode.
Lane
Use the jumper cap to switch the serial port communicaon
mode with the lane controller. By default, the interface is wired
and it is in RS-485 communicaon mode. If wiring other
controllers (compable with Hikvision communicaon
protocol), use the jumper cap to switch between RS-485 and
RS-232 communicaon mode.
UART4
The serial port is in the wiring interface according to the
picture above, which has a xed RS-232 communicaon mode
to communicate with the main lane controller. It contains no
jumper cap and cannot change the communicaon mode.
UART7/UART8
Reserved serial port. The serial port has a xed RS-232
communicaon mode. It contains no jumper cap and cannot
change the communicaon mode. The RS-232 interface's QR
code transmission database should no more than 64 bit.
The reserved interface posions in the turnsle and their
corresponded UART No. are as follows: