COOLING SYSTEM 4-11
Water Pump
•
Be sure to install the dowel pins [A].
•
Install:
Water Pump Housing [A]
Water Pump Impeller [B]
•
Tighten:
Torque - Water Pump Impeller Bolt [C]: 9.8 N·m (1.0 kgf·m,
87 in·lb)
•
Be sure to install the dowel pins [D].
•
Replace the O-ring [A] with a new one, and install it.
•
Install the water pump cover [A] and the clamp.
○
Touch the clamp to the boss [B] of the water pump cover.
•
Tighten:
Torque - Water Pump Cover Bolts [C]: 11 N·m (1.1 kgf·m, 97
in·lb)
•
Replace the O-ring [D] with new ones.
•
Install the water pipes [A] to the water pump cover.
•
Apply a non-parmanent locking agent to the threads of
the water pipe bolts [B], and tighten them.
Torque - Water Pipe Bolts: 12 N·m (1.2 kgf·m, 106 in·lb)
•
Install the water hose [C].
•
Tighten:
Torque - Water Hose Clamp Screw [D]: 2.9 N·m (0.30 kgf·m,
26 in·lb)
•
Connect the neutral switch connector [E].