CONSULT-II Application Items
NAEL0382
“RETAINED PWR”
NAEL0382S01
Data Monitor
NAEL0382S0101
Monitored Item Description
IGN ON SW Indicates [ON/OFF] condition of ignition switch.
DOOR SW-DR Indicates [ON/OFF] condition of front door switch LH.
DOOR SW-AS Indicates [ON/OFF] condition of front door switch RH.
Active Test
NAEL0382S0102
Test Item Description
RETAINED PWR This test is able to supply RAP signal (power) from smart entrance control unit to power window
system, power sunroof system and headlamp battery saver control unit. Those systems can be
operated when turning on “RETAINED PWR” on CONSULT-II screen even if the ignition switch is
tuned OFF.
NOTE:
During this test, CONSULT-II can be operated with ignition switch in “OFF” position.
“RETAINED PWR” should be turned “ON” or “OFF” on CONSULT-II screen when ignition
switch is ON. Then turn ignition switch OFF to check retained power operation. CON-
SULT-II might be stuck if “RETAINED PWR” is turned “ON” or “OFF” on CONSULT-II screen
when ignition switch is OFF.
Work Support
NAEL0382S0103
Work Item Description
RETAINED PWR SET Rap signal’s power supply period can be changed by mode setting. Selects rap signal’s power
supply period between three steps.
I MODE 1 (45 sec.)/MODE 2 (OFF)/MODE 3 (2 min.)
Trouble Diagnoses
NAEL0383
Symptom Possible cause Repair order
None of the power windows can be
operated using any switch.
1. 7.5A fuse, 40A fusible link
2. M145 circuit breaker
3. Power window relay
4. M145 circuit breaker circuit
5. Power window relay circuit
6. Ground circuit
7. Power window main switch
1. Check 7.5A fuse [No. 11, located in fuse block
(J/B)], 40A fusible link (letter f, located in fuse and
fusible link box).
2. Check M145 circuit breaker.
3. Check power window relay.
4. Check the following.
a. Harness between M145 circuit breaker and 40A fus-
ible link
b. Harness between M145 circuit breaker and front
power window main switch
5. Check the following.
a. Harness between 7.5A fuse and power window relay
b. Harness between M145 circuit breaker and power
window relay
6. Check the following.
a. Ground circuit of power window main switch terminal
5
b. Power window relay ground circuit
7. Check power window main switch.
POWER WINDOW