DTC P0011 IVT CONTROL
EC-639
[QR (WITHOUT EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
M
A
EC
CONSULT-II Reference Value in Data Monitor Mode BBS001N0
Specification data are reference values.
On Board Diagnosis Logic BBS001N1
The MI will not light up for this diagnosis.
FAIL-SAFE MODE
ECM enters in fail-safe mode when the malfunction is detected.
DTC Confirmation Procedure BBS001N2
CAUTION:
Always drive at a safe speed.
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is between 10V and 16V at
idle.
WITH CONSULT-II
1. Turn ignition switch ON and select “DATA MONITOR” mode with
CONSULT-II.
2. Start engine and warm it up to the normal operating tempera-
ture.
3. Maintain the following conditions for at least 6 consecutive sec-
onds.
Hold the accelerator pedal as steady as possible.
MONITOR ITEM CONDITION SPECIFICATION
INT/V TIM (B1)
● Engine: After warming up
● Shift lever: P or N (A/T), Neutral
(M/T)
● Air conditioner switch: OFF
● No load
Idle −5° - 5°CA
2,000 rpm Approx. 0° - 20°CA
INT/V SOL (B1)
● Engine: After warming up
● Shift lever: P or N (A/T), Neutral
(M/T)
● Air conditioner switch: OFF
● No load
Idle 0% - 2%
2,000 rpm Approx. 0% - 50%
DTC No.
Trouble diagnosis
name
Detecting condition Possible cause
P0011
0011
Intake valve timing
control performance
There is a gap between angle of target and
phase-control angle degree.
● Harness or connectors
(Intake valve timing control solenoid valve
circuit is open or shorted.)
● Intake valve timing control solenoid valve
● Crankshaft position sensor (POS)
● Camshaft position sensor (PHASE)
● Accumulation of debris to the signal pick-up
portion of the camshaft
Detected items Engine operating condition in fail-safe mode
Intake valve timing control The signal is not energized to the solenoid valve and the valve control does not function
ENG SPEED
1,200 - 2,000 (A constant rotation is
maintained.)
SEF174Y