Remote Control Commands
R&S
®
NGP800
140User Manual 5601.5610.02 ─ 04
Parameters:
<Channel list> <list>
Example:
MEAS:ENER:RES (@1)
Resets the measured accumulated energy value at channel 1.
Usage: Setting only
MEASure[:SCALar]:ENERgy:STATe <arg0>[, <Channel list>]
MEASure[:SCALar]:ENERgy:STATe? [<Channel list>]
Sets or queries the energy counter state for the selected channel.
Parameters:
<state> 1
Activates the energy counter.
0
Deactivates the energy counter.
Parameters for setting and query:
<Channel list> <list>
Example:
INST OUT1
MEAS:ENER:STAT ON
MEAS:ENER:STAT?
MEAS:ENER:STAT? -> 1
Energy counter of Ch1 is enabled.
Example:
MEAS:ENER:STAT? (@1)
Queries the energy counter state at channel 1.
MEASure[:SCALar]:STATistic:COUNt? [<Channel list>]
MEASure[:SCALar]:STATistic:COUNt?? [<Channel list>]
Returns the number of samples measured in the statistics for voltage/current/power
Parameters:
<Channel list> <list>
Example:
MEAS:STAT:COUN? (@1)
Queries the number of measurements at channel 1.
Usage: Query only
MEASure[:SCALar]:STATistic:RESet [<Channel list>]
MEASure[:SCALar]:STATistic:RESet [<Channel list>]
Resets the minimum, maximum and average statistic values for voltage, current, and
power.
Additionally this command resets the measured energy.
Parameters:
<Channel list> <list>
Measurement Commands