Remote Control Commands
R&S
®
NGP800
128User Manual 5601.5610.02 ─ 04
// ************************************************
// queries the upper and lower limit of the
// overcurrent protection delay time in ms
FUSE:DEL:INIT? MIN
// response: 10
FUSE:DEL:INIT? MAX
// response: 60000
// ************************************************
// Query a tripped overcurrent protection
// ************************************************
INST OUT1
//queries whether the OCP in channel 1 has tripped
FUSE:TRIP?
//response: 1 OCP is tripped
//response: 0 OCP is not tripped
//resets a tripped OCP in the selected channel
FUSE:TRIP:CLEar
// ************************************************
// Link the electronic overcurrent protection of the channels logically
// ************************************************
INST OUT1
// links the overcurrent protection of channel 1 with channel 2
FUSE:LINK 2
// queries the combined overcurrent protection of the selected channel
FUSE:LINK?
// ************************************************
// Unlink linked overcurrent protection
// ************************************************
FUSE:UNLink 2
// queries the combined overcurrent protection of the selected channel
FUSE:LINK?
//response 0
FUSE:TRIPped:CLEar....................................................................................................128
FUSE:DELay:INITial.......................................................................................................129
FUSE:DELay[:BLOWing]................................................................................................ 129
FUSE:LINK....................................................................................................................130
FUSE:TRIPped?............................................................................................................ 130
FUSE:UNLink................................................................................................................ 130
FUSE[:STATe]................................................................................................................131
FUSE:TRIPped:CLEar [<Channel list>]
FUSE:TRIPped:CLEar [<Channel list>]
Resets the OCP state of the selected channel. If an OCP event has occurred before,
the reset also erases the message on the display.
Parameters:
<Channel list> <list>
Configuration Commands