Rohde & Schwarz NGP814 power supply

NGP800 series manual - Page 124

For NGP814.

PDF File Manual, 190 pages, Read Online | Download pdf file

NGP814 photo
Loading ...
Loading ...
Loading ...
Remote Control Commands
R&S
®
NGP800
122User Manual 5601.5610.02 ─ 04
[SOURce:]CURRent[:LEVel][:IMMediate]:STEP[:INCRement] <desired stepsize>[,
<Optional default step query>]
[SOURce:]CURRent[:LEVel][:IMMediate]:STEP[:INCRement]? [<Optional default
step query>]
Sets or queries the incremental step size for the
CURR UP | CURR DOWN command.
Setting parameters:
<stepsize> <numeric value> | DEF | DEFault
<numeric value>
Step value in A.
DEF | DEFault
Default value of stepsize.
Range: 0.0001 to 2.000
Increment: 0.0001
*RST: 0.010
Default unit: A
Parameters for setting and query:
<Optional default step
query>
DEF | DEFault
Queries the default voltage step size.
Example:
INST OUT1
CURR:STEP 0.005
CURR:STEP DEF
VOLT:STEP? DEF -> 0.1000E+00
Returns the default stepsize for current.
See
Example "Configuring the current output" on page 120.
7.5.6 Combined Setting of Voltage and Current Settings
The APPLy subsystem provides a command that enables you to set the current and
voltage of a channel in one step.
The combined voltage and current setting command takes approximately 100 ms, i.e.
longer than the setting of a single value.
APPLy <arg0>[, <arg1>, <arg2>]
Sets or queries the voltage and current value of the selected channel.
Parameters:
<voltage> numeric | MIN | MINimum | MAX | MAXimum | DEF | DEFault
numeric
Numeric value for voltage in the range of 0.000 to 64.050.
MIN | MINimum
Min voltage at 0.000 V.
Configuration Commands
Loading ...
Loading ...
Loading ...