Remote Control Commands
R&S
®
NGP800
130User Manual 5601.5610.02 ─ 04
Example:
FUSE:DEL? (@1)
Queries fuse delay time at channel 1.
Example: See
Example "Configuring fuses" on page 127.
FUSE:LINK <arg0>...
FUSE:LINK? <arg0>...
Sets or queries the fuses of several selected channels (fuse linking).
Parameters for setting and query:
<arg0> 0 | 1 | 2 | 3 | 4
0 - Link all other channels to the previously selected channel.
Example:
INST OUT1;:FUSE:LINK 2
Channel 2 is linked with channel 1
INST OUT1;:FUSE:LINK?
Returns a comma-separated list of all channels linked to channel
1.
See
Example "Configuring fuses" on page 127.
FUSE:TRIPped? [<Channel list>]
FUSE:TRIPped?? [<Channel list>]
Queries the OCP state of the selected channel.
Parameters:
<Channel list> <list>
Example:
FUSE:TRIP?
Response 1, the OCP is tripped.
Response 0, the OCP is not tripped.
Example:
FUSE:TRIP? (@1)
Queries fuse tripped status at channel 1.
Usage: Query only
See
Example "Configuring fuses" on page 127.
FUSE:UNLink <arg0>...
Unlinks fuse linking from the other channels (Ch 1, Ch 2, Ch 3 or Ch 4).
See Example "Configuring fuses" on page 127.
Parameters:
<arg0> 0 | 1 | 2 | 3 | 4
0 - Unlink all other channels to the previously selected channel.
Example:
FUSE:UNL 1
Fuse linking is unlinked from channel 1
Usage: Setting only