Rohde & Schwarz NGP814 power supply

NGP800 series manual - Page 115

For NGP814.

PDF File Manual, 190 pages, Read Online | Download pdf file

NGP814 photo
Loading ...
Loading ...
Loading ...
Remote Control Commands
R&S
®
NGP800
113User Manual 5601.5610.02 ─ 04
[SOURce:]ALIMit[:STATe] <arg0>[, <Channel list>]
[SOURce:]ALIMit[:STATe]? [<Channel list>]
Sets or queries the safety limit state.
Parameters:
<state> 1
Activates the safety limit.
0
Deactivates the safety limit.
Parameters for setting and query:
<Channel list> <list>
Example:
ALIM 1, (@1)
Activates the safety limit state at channel 1
Example: See
Example "Configuring the safety limit" on page 112.
[SOURce:]VOLTage[:LEVel][:IMMediate]:ALIMit:LOWer <New value for voltage>[,
<Channel list>]
[SOURce:]VOLTage[:LEVel][:IMMediate]:ALIMit:LOWer? [<Channel list>]
Sets or queries the lower safety limit for voltage.
Setting parameters:
<voltage> <numeric value> | MIN | MINimum | MAX | MAXimum
<numeric value>
Numeric value for safety limit.
MIN | MINimum
Min value for lower safety limit.
MAX | MAXimum
Max value for lower safety limit.
Range: 0.000E+00 to 6.4050E+01
Increment: 0.001
*RST: 0.000E+00
Parameters for setting and query:
<Channel list> <list>
Example:
VOLT:ALIM:LOW? (@1)
Queries the lower safety limit for voltage at channel 1
Example: See
Example "Configuring the safety limit" on page 112.
[SOURce:]VOLTage[:LEVel][:IMMediate]:ALIMit[:UPPer] <New value for voltage>
[SOURce:]VOLTage[:LEVel][:IMMediate]:ALIMit[:UPPer]? [<Channel list>]
Sets or queries the upper safety limit for voltage.
Setting parameters:
<voltage> <numeric value> | MIN | MINimum | MAX | MAXimum
Configuration Commands
Loading ...
Loading ...