Remote Control Commands
R&S
®
NGP800
115User Manual 5601.5610.02 ─ 04
[SOURce:]CURRent[:LEVel][:IMMediate]:ALIMit[:UPPer] <New value for current>[,
<Channel list>]
[SOURce:]CURRent[:LEVel][:IMMediate]:ALIMit[:UPPer]? [<Channel list>]
Sets or queries the upper safety limit for current.
Setting parameters:
<current> <numeric value> | MIN | MINimum | MAX | MAXimum
<numeric value>
Numeric value for upper safety limit.
MIN | MINimum
Min value for upper safety limit.
MAX | MAXimum
Max value for upper safety limit.
Range: For up to 32V: 0.0005E+00 to 20.0100E+00. For up
to 64V: 0.0005E+00 to 10.0100E+00
Increment: 0.0005
*RST: 0.0005E+00
Parameters for setting and query:
<Channel list> <list>
Example:
CURR:ALIM:UPP? (@1)
Queries the upper safety limit for current at channel 1.
Example: See
Example "Configuring the safety limit" on page 112.
7.5.3 Remote Sense Setting
The VOLTage:SENSe subsystem contains the command for setting the remote sense
for the instrument.
[SOURce:]VOLTage:SENSe[:SOURce].............................................................................115
[SOURce:]VOLTage:SENSe[:SOURce] <arg0>[, <Channel list>]
[SOURce:]VOLTage:SENSe[:SOURce]? [<Channel list>]
Sets remote sense detection.
Parameters:
<detection> AUTO | EXT | <list>
AUTO
If remote sense detection is set "AUTO", the detection and ena-
bling of the voltage sense relay automatically kicks in when the
connection of remote sense wires (S+, S-) to the input of the
load is applied.
Configuration Commands
Loading ...
Loading ...
Loading ...