Rohde & Schwarz NGP814 power supply

NGP800 series manual - Page 139

For NGP814.

PDF File Manual, 190 pages, Read Online | Download pdf file

NGP814 photo
Loading ...
Loading ...
Loading ...
Remote Control Commands
R&S
®
NGP800
137User Manual 5601.5610.02 ─ 04
Parameters for setting and query:
<Channel list> <list>
Example:
POW:PROT:LEV? (@1)
Queries OPP value at channel 1.
Example: See
Example "Configuring the overpower protection"
on page 135.
[SOURce:]POWer:PROTection:TRIPped? [<Channel list>]
[SOURce:]POWer:PROTection:TRIPped?? [<Channel list>]
Queries the OPP state of the selected channel.
Parameters:
<Channel list> <list>
Example:
POW:PROT:TRIP?
Response 1, the OPP is tripped.
Response 0, the OPP is not tripped.
Example:
POW:PROT:TRIP? (@1)
Queries OPP state at channel 1.
Usage: Query only
See
Example "Configuring the overpower protection" on page 135.
7.5.11 Reset Protection Tripped State
The Protection subsystem contains the command to reset the protection tripped
state.
[SOURce:]PROTection:CLEar [<Channel list>]
Reset protection tripped state.
Parameters:
<Channel list> <list>
Example:
PROT:CLE (@1)
Reset protection tripped state at channel 1.
Usage: Setting only
7.5.12 Tracking Setting
The TRACking subsystem contains the commands for changes made on reference
channel are applied to the tracked channels.
TRACking[:ENABle]:CH<CHANNEL>...............................................................................138
TRACking[:ENABle]:GENeral.......................................................................................... 138
TRACking[:ENABle]:SELect:CH<CHANNEL>................................................................... 138
Configuration Commands
Loading ...
Loading ...
Loading ...