Remote Control Commands
R&S
®
NGL200/NGM200
156User Manual 1178.8736.02 ─ 09
[SOURce:]VOLTage:RAMP:DURation <duration>
[SOURce:]VOLTage:RAMP:DURation? [<Channel list>]
Sets or queries the duration of the voltage ramp.
Parameters:
<duration> <numeric value> | MIN | MINimum | MAX | MAXimum | DEF |
DEFault | <list>
<numeric value>
Duration of the ramp function in seconds.
MIN | MINimum
Minimum duration of the ramp function at 0.00 s.
MAX | MAXimum
Minimum duration of the ramp function at 10 s.
DEF | DEFault
Default duration of the ramp function at 0.01 s.
Range: 0.01 to 10.00
*RST: 0.01
Default unit: s
Parameters for setting and query:
<Channel list> <list>
Example:
VOLT:RAMP:DUR 4
VOLT:RAMP:DUR? -> 4
Duration of the ramp function is set at 4 s.
Example:
VOLT:RAMP:DUR 4, (@1)
VOLT:RAMP:DUR? (@1)
Sets and queries the duration of ramp function at channel 1.
7.7.3 Digital I/O
The DIO subsystem contains the commands for configuring a Digital I/O function for
the output channels.
DIO:FAULt:CHANnel...................................................................................................... 156
DIO:FAULt:SOURce.......................................................................................................157
DIO:FAULt[:STATe].........................................................................................................157
DIO:FAULt:SIGNal......................................................................................................... 158
DIO:OUTPut:SOURce.................................................................................................... 158
DIO:OUTPut[:STATe]...................................................................................................... 158
DIO:OUTPut:SIGNal.......................................................................................................159
DIO:FAULt:CHANnel <arg0>
DIO:FAULt:CHANnel?
Sets or queries channel selection for the digital output fault source.