Rohde & Schwarz NGM-COM2B Rohde &Schwarz power supply bundle

User manual NGM COM2a - Page 106

For NGM-COM2B.

PDF File Manual, 201 pages, Read Online | Download pdf file

NGM-COM2B photo
Loading ...
Loading ...
Loading ...
Remote Control Commands
R&S
®
NGL200/NGM200
104User Manual 1178.8736.02 ─ 09
TRIGger[:SEQuence][:IMMediate]:SOURce:DIO:PIN <arg0>
TRIGger[:SEQuence][:IMMediate]:SOURce:DIO:PIN? <arg0>
Sets or queries the DIO pin to trigger on for trigger source "Digital In Channel".
See
Figure 6-18.
Parameters for setting and query:
<arg0> IN | EXT
IN
Pin 3 of DIO connector is monitored.
EXT
Pin 2 (Ch1) and Pin 10 (Ch2) of DIO connector is monitored.
Example:
TRIG:SOUR:DIO:PIN IN
Pin 3 of DIO connector is monitored for trigger source "Digital In
Channel".
TRIGger[:SEQuence][:IMMediate]:SOURce:OMODe <arg0>
TRIGger[:SEQuence][:IMMediate]:SOURce:OMODe? <arg0>
Sets or queries the operation mode to trigger on for trigger source "operation mode"
See
Figure 6-18.
Parameters for setting and query:
<arg0> CC | CV | CR | SINK | PROTection
CC
If respective channel operation mode is detected in CC mode,
corresponding trigger-out parameters are triggered.
CV
If respective channel operation mode is detected in CV mode,
corresponding trigger-out parameters are triggered.
CR
If respective channel operation mode is detected in CR mode,
corresponding trigger-out parameters are triggered.
SINK
If respective channel operation mode is detected in sink mode,
corresponding trigger-out parameters are triggered.
PROTection
If respective channel operation mode is detected in protection
mode (OVP, OCP, OPP OTP), corresponding trigger-out param-
eters are triggered.
Example:
TRIG:SOUR OMOD
TRIG:SOUR:OMOD:CHAN OUT1
TRIG:SOUR:OMOD CV
If CV mode is detected on Ch1, a trigger event is activated to
corresponding trigger-out parameters.
Trigger Commands
Loading ...
Loading ...
Loading ...