Rohde & Schwarz NGM-COM2B Rohde &Schwarz power supply bundle

User manual NGM COM2a - Page 112

For NGM-COM2B.

PDF File Manual, 201 pages, Read Online | Download pdf file

NGM-COM2B photo
Loading ...
Loading ...
Loading ...
Remote Control Commands
R&S
®
NGL200/NGM200
110User Manual 1178.8736.02 ─ 09
*RST: 2.050E+01
Parameters for setting and query:
<Channel list> <list>
Example:
VOLT:ALIM:UPP? (@1)
Queries the upper safety limit for voltage at channel 1.
Example: See
Example "Configuring the output voltage" on page 112.
[SOURce:]CURRent[:LEVel][:IMMediate]:ALIMit:LOWer <current>
[SOURce:]CURRent[:LEVel][:IMMediate]:ALIMit:LOWer? [<Channel list>]
Sets or queries the lower safety limit for current.
Setting parameters:
<current> <numeric value> | MIN | MINimum | MAX | MAXimum | <list>
<numeric value>
Numeric value for lower safety limit.
MIN | MINimum
Min value for lower safety limit.
MAX | MAXimum
Max value for lower safety limit.
Range: For up to 6V: 0.001E+00 to 3.010E+00. For above
6V: 0.001E+00 to 6.010E+00
Increment: 0.001
*RST: 0.001E+00
Parameters for setting and query:
<Channel list> <list>
Example:
CURR:ALIM:LOW? (@1)
Queries the lower safety limit for current at channel 1.
Example: See
Example "Configuring the current output" on page 115.
[SOURce:]CURRent[:LEVel][:IMMediate]:ALIMit[:UPPer] <current>
[SOURce:]CURRent[:LEVel][:IMMediate]:ALIMit[:UPPer]? [<Channel list>]
Sets or queries the upper safety limit for current.
Setting parameters:
<current> <numeric value> | MIN | MINimum | MAX | MAXimum | <list>
<numeric value>
Numeric value for upper safety limit.
MIN | MINimum
Min value for upper safety limit.
MAX | MAXimum
Max value for upper safety limit.
Range: For up to 6V: 0.001E+00 to 3.010E+00. For above
6V: 0.001E+00 to 6.010E+00
Configuration Commands
Loading ...
Loading ...
Loading ...