Remote Control Commands
R&S
®
NGL200/NGM200
123User Manual 1178.8736.02 ─ 09
Example:
OUTPut:DELay:DURation 1
OUTPut:DELay:DURation? -> 1
Returns output delay of 1 s.
Example:
OUTPut:DELay:DURation? (@1)
Returns output delay at channel 1.
OUTPut:DELay[:STATe] <state>
OUTPut:DELay[:STATe]? [<Channel list>]
Sets or queries the output delay state for the selected channel.
Parameters:
<state> 0
Deactivates output delay for the selected channel.
1
Activates output delay for the selected channel.
Parameters for setting and query:
<Channel list> <list>
Example:
OUTPut:DELay 1
OUTPut:DELay? -> 1
Returns output delay state as on.
Example:
OUTPut:DELay? (@1)
Returns output delay state at channel 1.
OUTPut:FTResponse <state>
OUTPut:FTResponse? [<Channel list>]
Sets or queries the fast transient response state.
Parameters:
<state> 0
Deactivates fast transient response.
1
Activates fast transient response.
Parameters for setting and query:
<Channel list> <list>
Example:
OUTPut:FTResponse 1
OUTPut:FTResponse? -> 1
Returns fast transient response state as on.
Example:
OUTPut:FTR? (@1)
Returns fast transient response state at channel 1.