24
To connect the clamp cable
1. Connect the tubular plug of the clamp cable to the male connector of the
auxiliary power outlet adapter.
Figure 4-1 Connection between Auxiliary Power Outlet Adapter and Clamp Cable
2. Plug the DC power connector of the auxiliary power outlet adapter into the DC
power supply input port of the VCMI device.
3. Connect the clamp cable to the vehicle's battery.
NOTE
After the VCMI device is successfully connected to the vehicle, the Power LED on the
device lights, and a beeping sound will be heard.
VCMI Connection
After the VCMI device is properly connected to the vehicle, the Power LED on the VCMI
device lights solid green, and is ready to establish communication with the tablet.
Coming with the MaxiSys Ultra EV tool kit, the VCMI device supports three
communication methods with the tablet: BT, Wi-Fi and USB.
Pairing Up via BT
In open areas, the working range for BT communication is about 328 feet (100 m), giving
technicians greater mobility to perform vehicle diagnosis from anywhere in the repair
shop.
To expedite multi-vehicle diagnostics, more than one VCMI can be used in busy repair
shops, enabling technicians to quickly pair their Ultra EV to each VCMI separately via BT
without the need to unplug the VCMI from one vehicle and then connect it to another
each time.
To pair the tablet with the VCMI device via BT
1. Power up the tablet.
2. Select the VCMI Manager application on the MaxiSys Job Menu.
3. When the VCMI Manager application is opened, select VCMI BT, and the
device automatically scans for available VCMI devices for BT pairing. The found