The amplitude settings allow you to set up the multimeter to capture signals within
the specified range. If the input signal exceeds the selected range, an over-range
indicator will be displayed. Select Auto to enable the device to adjust the vertical
scale automatically.
There are two modes available to set the amplitude value.
Mode 1: For example, selecting DC voltage in Measurement setting screen sets the
measurement type to DC voltage, selecting 10V in Amplitude setting screen sets the
amplitude to Amplitude 10V (displays on the lower left corner of the screen). The
vertical scale range is from -10V to +10V. As the vertical scale is divided into 10
segments, each segment increases by 2V.
Figure 9-84 Amplitude Setting Screen (DC 10V)
Mode 2: Select the ## /div button to adjust the value increments of each division.
For example, selecting DC voltage in Measurement setting screen, sets the
measurement type to DC voltage . Selecting 2.0V/div in Amplitude setting screen,
sets the amplitude to Amplitude 2.0 V/div (displays on the lower left corner of the
screen) . Each segment increases by 2V. As the vertical scale is divided into 10
segments, the entire vertical scale range is from -10V to +10V.