173
upper threshold
Fall Time — the time the signal takes to fall from the upper threshold to the
lower threshold
X@Max — the corresponding value of X axis when the amplitude is the
maximum
X@ Min — the corresponding value of X axis when the amplitude is the
minimum
Positive Acreage — the waveform acreage measured above the zero
baseline
Negative Acreage — the waveform acreage measured below the zero
baseline
Full Acreage — the positive acreage plus negative acreage
Top Value — 90% of the waveform maximum value
Bottom Value — 10% of the waveform minimum value
Positive Overshoot — the ratio of the difference between the maximum value
and the top value and the amplitude
Negative Overshoot — the ratio of the difference between the bottom value
and the minimum value and the amplitude
Positive Pre-shoot — the ratio of the difference between the bottom value
and the minimum value and the amplitude
Negative Pre-shoot —the ratio of the difference between the maximum value
and the top value and the amplitude
NOTE
When connecting via Wi-Fi ,it only supports Maximum, Minimum, Peak To Peak,
Amplitude, Period, Frequency, Positive Duty Ratio, Negative Duty Ratio, Positive
Pulse Width, Negative Pulse Width, AC RMS, True RMS, DC Average, X@Max,
X@Min, Top Value and Bottom Value.
In the Spectrum View, the available measurements are as follows.