Maintenance
346
ProSAFE 10-Gigabit Smart Managed Switch XS728T and XS748T User Manual
2. Launch a web browser.
3. In the address field of your web browser, enter the IP address of the switch.
If you do not know the IP address of the switch, see Change the Default IP Address of the
Switch on page 10.
The login window opens.
4. Enter the switch’s password in the Password field.
The default password is password.
The System Information page displays.
5. Select Maintenance > Troubleshooting > Ping IPv6.
6. From the Ping menu, select the type of ping:
Global. Pings a global IPv6 address.
Link Local. Pings a link-local IPv6 address over a specified interface. With this
selection, the Interface menu displays, and you must select the interface.
7. In the IPv6 Address/Hostname field, enter the IPv6 address or host name of the station
that must be pinged.
The format is xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx. The maximum number of
characters is 160.
8. In the Datagram Size field, enter the datagram size.
The valid range is 48 to 2048. The default value is 64 bytes.
9. Click the Apply button.
The specified address is pinged. The results are displayed below the configurable data in
the Results field.
If a reply to the ping is received, a message similar to the following one is displayed:
Send count=3, Receive count = n from (IPv6 Address). Average round-trip time = n ms.
If a reply to the ping is not received, a message similar to the following one is displayed:
Send count = 3, Receive count = 0 from IP/HOST Average round trip time = 680 ms.