Configure Routing
177
ProSAFE 10-Gigabit Smart Managed Switch XS728T and XS748T User Manual
The following table describes the nonconfigurable information displayed on the page.
Configure the Global Aging-Out Time for ARP
You can change the global aging-out time for the ARP table. The aging-out time is the period
after which an entry in the ARP is automatically deleted.
To configure the global aging-out time for the ARP table:
1. Connect your computer to the same network as the switch.
You can use a WiFi or wired connection to connect your computer to the network, or
connect directly to a switch that is off-network using an Ethernet cable.
2. Launch a web browser.
3. In the address field of your web browser, enter the IP address of the switch.
If you do not know the IP address of the switch, see Change the Default IP Address of the
Switch on page 10.
The login window opens.
4. Enter the switch’s password in the Password field.
The default password is password.
The System Information page displays.
5. Select Routing> ARP > Advanced > Global ARP Configuration.
The Global ARP Configuration page displays.
6. In the Age Time (secs) field, enter the time, in seconds, that a dynamic ARP entry remains
in the ARP table before aging out.
The range is 15 to 21600 seconds. The default value is 1200 seconds.
7. Click the Apply button.
The updated configuration is sent to the switch. Configuration changes take effect
immediately.
Table 46. Routing VLANs ARP Cache information
Field Description
Interface The routing interface associated with the ARP entry.
IP Address The IP address of the device (on a subnet) that is attached an existing routing interface
of the switch.
MAC Address The unicast MAC address of the attached device. The address is six two-digit
hexadecimal numbers separated by colons, for example, 00:06:29:32:81:40.
Type The type of ARP entry. Possible values are as follows:
Static. An ARP entry that was manually configured.
Dynamic. An ARP entry that was learned by the router.