Configure Switching
101
ProSAFE 10-Gigabit Smart Managed Switch XS728T and XS748T User Manual
7. Do one of the following:
To configure a single interface, select the check box associated with the interface, or
type the interface number in the Go To Interface field and click the Go button.
To configure multiple interfaces with the same settings, select the check box
associated with each interface.
To configure all interfaces with the same settings, select the check box in the heading
row.
8. In the PVID field, specify the VLAN ID to assign to untagged or priority-tagged frames
received on this port.
The default is 1.
9. In the VLAN Member field, specify the VLAN ID or list of VLANs of a member port.
VLAN IDs range from 1 to 4093. The default is 1. Use a hyphen (-) to specify a range or a
comma (,) to separate VLAN IDs in a list. Spaces and zeros are not permitted.
10. In the VLAN Tag field, specify the VLAN ID or list of VLANs of a tagged port.
VLAN IDs range from 1 to 4093. Use a hyphen (-) to specify a range or a comma (,) to
separate VLAN IDs in a list. Spaces and zeros are not permitted. To reset the VLAN tag
configuration to the defaults, use the None keyword. Port tagging for the VLAN can be
set only if the port is a member of this VLAN.
11. From the Acceptable Frame menu, specify the types of frames that can be received on this
port.
The options are VLAN only and Admit All:
VLAN only. Untagged frames or priority-tagged frames received on this port are
discarded.
Admit All. Untagged frames or priority-tagged frames received on this port are
accepted and assigned the value of the port VLAN ID for this port. With either option,
VLAN-tagged frames are forwarded in accordance to the 802.1Q VLAN specification.
12. From the Ingress Filtering menu, select one of the following options:
Enable. The frame is discarded if this port is not a member of the VLAN with which
this frame is associated. In a tagged frame, the VLAN is identified by the VLAN ID in
the tag. In an untagged frame, the VLAN is the port VLAN ID specified for the port that
received this frame. The default is Enable.
Disable. All frames are forwarded in accordance with the 802.1Q VLAN bridge
specification.
13. In the Port Priority field, specify the default 802.1p priority assigned to untagged packets
arriving at the port.
You can enter a number from 0 to 7.
14. Click the Apply button.
The updated configuration is sent to the switch. Configuration changes take effect
immediately.