Configure Routing
186
ProSAFE 10-Gigabit Smart Managed Switch XS728T and XS748T User Manual
A value of 0 means the interval is not specified for the router. The range of the neighbor
solicit interval is 1000 to 4294967295. The default is 0.
13. In the Adv Reachable Interval field, specify the router advertisement time.
This is the time allocated to consider the neighbors reachable after ND confirmation. The
range of reachable time is 0 to 3600000. The default is 0.
14. Use the Adv Interval field to specify the maximum time allowed between sending router
advertisements from the VLAN.
The range of the maximum advertisement interval is 4 to 1800. The default value is 600.
15. From the Adv Managed Config Flag menu, specify the setting for the router advertisement
managed address configuration flag.
When you select Enable, end nodes use DHCPv6. When you select Disable, end nodes
autoconfigure addresses. The default value is Disable.
16. From the Adv Other Config Flag menu, select to enable or disable the router
advertisement other stateful configuration flag.
The default value is Disable.
17. From the Adv Suppress Flag menu, select to enable or disable the router advertisement
suppression on the VLAN.
The default value is Disable.
18. From the Destination Unreachables menu, select to enable or disable the mode for
sending ICMPv6 destination unreachable messages from the VLAN.
If this mode is disabled, the VLAN does not send ICMPv6 destination unreachable
messages. By default, the IPv6 destination unreachables mode is enabled.
19. Click the Apply button.
The updated configuration is sent to the switch. Configuration changes take effect
immediately.
The following table describes the nonconfigurable data that is displayed.
Add an IPv6 Global Address to an IPv6 VLAN
IPv6 link-local addresses are created automatically when you enable the IPv6 admin mode
on an VLAN interface, and they cannot be removed or edited. However, you can manually
configure IPv6 global addresses on a VLAN.
Table 48. IPv6 VLAN Configuration information
Field Description
Operational Mode The operational mode of the VLAN (Enable or Disable).
Link State The state of the link (Link Up or LInk Down).