User Manual - Page 790

For X-TRAIL.

Loading ...
Loading ...
Loading ...
EC-790
[QR (WITHOUT EURO-OBD)]
HO2S1
4. CHECK HO2S1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between ECM terminal 35 and HO2S1 terminal 2.
Refer to Wiring Diagram.
2. Check harness continuity between ECM terminal 35 or HO2S1 terminal 2 and ground.
Refer to Wiring Diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK HEATED OXYGEN SENSOR 1
Refer to EC-790, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace heated oxygen sensor 1.
6. CHECK INTERMITTENT INCIDENT
Refer to EC-570, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>> INSPECTION END
Component Inspection EBS0113P
HEATED OXYGEN SENSOR 1
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select “MANU TRIG” and adjust “TRIGGER POINT” to 100% in “DATA MONITOR” mode with CONSULT-
II.
3. Select “HO2S1 (B1)” and “HO2S1 MNTR (B1)”.
4. Hold engine speed at 2,000 rpm under no load during the follow-
ing steps.
5. Touch “RECORD” on CONSULT-II screen.
6. Check the following.
“HO2S1 MNTR (B1)” in “DATA MONITOR” mode changes
from “RICH” to “LEAN” to “RICH” more than 5 times in 10 sec-
onds.
5 times (cycles) are counted as shown at right.
“HO2S1 (B1)” voltage goes above 0.6V at least once.
“HO2S1 (B1)” voltage goes below 0.3V at least once.
“HO2S1 (B1)” voltage never exceeds 1.0V.
Continuity should exist.
Continuity should not exist.
SEF646Y
SEF217YA
Loading ...
Loading ...