EC-1258
[YD (WITHOUT EURO-OBD)]
TROUBLE DIAGNOSIS
NOTE:
Any monitored item that does not match the vehicle being diagnosed is deleted from the display automatically.
*: These signals are converted by ECM internally. Thus, these differ from ECM terminals voltage.
P/N POSI SW
Ignition switch: ON
Shift lever: Neutral position ON
Except above OFF
START SIGNAL
Ignition switch: ON START ON OFF ON OFF
PW/ST SIGNAL
Engine: After warming up, idle
the engine
Steering wheel is in neutral posi-
tion. (Forward direction)
OFF
Steering wheel is turned. ON
BRAKE SW
Ignition switch: ON
Brake pedal: Fully released OFF
Brake pedal: Slightly depressed ON
IGN SW
Ignition switch: ON OFF ON OFF
ACT CR PRESS
Engine: After warming up
Air conditioner switch: OFF
Shift lever: Neutral position
No-load
Idle 20 - 30 MPa
2,000 rpm 45 - 55 MPa
MAIN INJ WID
Engine: After warming up
Shift lever: Neutral position
Idle speed
No-load 0.68 - 0.78 msec
Blower fan switch: ON
Rear window defogger switch: ON
0.78 - 0.88 msec
GLOW RLY Refer to EC-1457, "
GLOW CONTROL SYSTEM" .
PUMP CURRENT
Engine: After warming up
Air conditioner switch: OFF
Shift lever: Neutral position
No-load
Idle 1,700 - 1,900 mA
2,000 rpm 1,600 - 1,800 mA
COOLING FAN
When cooling fan is stopped. OFF
When cooling fans operate at low speed. LOW
When cooling fans operate at high speed. HI
EGR VOL CON/V
Engine: After warming up
Air conditioner switch: OFF
Shift lever: Neutral position
No-load
After 1 minute at idle More than 10 steps
Revving engine from idle to 3,600
rpm
0 step
INT/A VOLUME
Engine: After warming up, idle the engine 150 - 450 mg/st
INT/M PRES SE [kPa]
Engine: After warming up
Air conditioner switch: OFF
Shift lever: Neutral position
No-load
Idle Approx. 100 kPa
2,800 rpm Approx. 126 kPa
4,000 rpm Approx. 106 kPa
BARO SEN
Ignition switch: ON
Altitude
Approx. 0m: Approx. 100.62 kPa
(1.0062 bar, 1.026 kg/cm
2
, 14.59
psi)
Approx. 1,000 m: Approx. 88.95
kPa (0.8895 bar, 0.907 kg/cm
2
,
12.90 psi)
Approx. 1,500 m: Approx. 83.16
kPa (0.8316 bar, 0.848 kg/cm
2
,
12.06 psi)
Approx. 2,000 m: Approx. 78.36
kPa (0.7836 bar, 0.799 kg/cm
2
,
11.36 psi)
CYL COUNT Engine is running 1 3 4 2